Skip to content
fE1C0mBhG.png__PID:09a425ba-9b9f-46fa-bbfa-87f184931077

V-bank HEPA filters

Clean-Link supplies high-temperature HEPA filters for ovens, drying systems, process ventilation, pharmaceutical facilities, and industrial equipment.
Available options include H13/H14 requirements, separator construction, metal frames, custom sizes, and gasket configurations. Filter selection should consider airflow, pressure drop, continuous temperature, peak temperature, and complete filter construction.

Compact High-Efficiency V-Bank Filter

EN779:
ISO16890:
Original price $0.00 - Original price $0.00
Original price
$0.00
$0.00 - $0.00
Current price $0.00

Technical Data  

Clean-Link supplies V-bank HEPA filters for high-airflow HVAC systems, industrial ventilation, data centers, laboratories, pharmaceutical facilities, cleanroom-related HVAC systems, commercial buildings, and OEM equipment.

V-bank construction uses multiple mini-pleat media packs arranged in a V-shaped configuration. This design increases media area within a compact filter footprint and can help balance high filtration efficiency, airflow capacity, pressure drop, and service life.

Clean-Link can support H13 and H14 project requirements, rigid frame configurations, custom dimensions, gasket options, airflow and pressure drop review, and OEM or project-based V-bank HEPA filter supply.

V-Bank HEPA Filter Products

H13 V-Bank HEPA Filter

Designed for high-efficiency final filtration in high-airflow HVAC and industrial ventilation systems.

Typical options may include:

  • H13 project requirements
  • Multiple V-shaped mini-pleat media packs
  • Rigid frame construction
  • Custom dimensions
  • Gasket options
  • Rated airflow review
  • Pressure drop review

H14 V-Bank HEPA Filter

For applications requiring H14 final filtration with a compact high-media-area structure.

Typical options:

  • H14 project requirement
  • V-bank mini-pleat construction
  • Custom airflow
  • Custom frame dimensions
  • Gasket configurations
  • OEM packaging or bulk supply

High-Airflow V-Bank HEPA Filter

Designed for systems where high airflow must be handled within limited installation space.

Typical applications include:

  • Large AHUs
  • Data center cooling systems
  • Industrial ventilation
  • Laboratories
  • Commercial buildings
  • Process air systems

Custom V-Bank HEPA Filter

For OEM systems, non-standard housings, retrofit projects, or replacement programs.

Custom options may include:

  • Length, width and depth
  • Number of V-shaped media packs
  • H13 / H14
  • Frame material
  • Gasket
  • Rated airflow
  • Pressure drop target
  • Packaging
  • Drawing or sample matching

Request Custom Specification →

What Is a V-Bank HEPA Filter?

A V-bank HEPA filter uses multiple mini-pleat filter packs arranged in a V-shaped configuration inside a rigid frame.

This design increases the effective media area without requiring a much larger filter face.

The larger media area can help support:

  • Higher airflow
  • Lower media face velocity
  • Pressure drop optimization
  • High-efficiency filtration
  • Compact installation
  • Longer service potential under suitable loading conditions

The actual performance depends on filter dimensions, media area, efficiency class, pleat geometry, rated airflow, and system conditions.

Why Use V-Bank Construction?

High Media Area in a Compact Footprint

The main advantage of V-bank construction is that multiple media packs can be installed within one rigid filter frame.

This creates more filtration surface area than a flat filter of similar face dimensions.

Higher media area can help reduce the velocity through the media and support better airflow handling.

Suitable for High Airflow

V-bank filters are often used in systems where a large amount of air must pass through a limited filter face area.

Typical high-airflow applications include:

  • Large commercial AHUs
  • Industrial ventilation systems
  • Data center HVAC
  • Laboratory ventilation
  • Critical building ventilation
  • OEM air handling equipment

The actual rated airflow should always be confirmed from the filter specification rather than assumed from the V-bank structure alone.

Pressure Drop Optimization

A V-bank HEPA filter can provide more media area than some conventional flat or compact filter formats.

This can help optimize pressure drop for the required airflow.

However, V-bank does not automatically mean “low pressure drop.”

Actual resistance depends on:

  • Media area
  • Efficiency class
  • Filter depth
  • Number of media packs
  • Pleat geometry
  • Rated airflow
  • Face velocity
  • Filter loading

Clean-Link can review airflow and pressure drop requirements for project-based V-bank HEPA filters.

V-Bank HEPA vs Mini-Pleat HEPA Filters

V-bank HEPA filters usually use mini-pleat media packs, but the overall filter construction is different from a conventional single-pack mini-pleat HEPA filter.

Feature V-Bank HEPA Filter Standard Mini-Pleat HEPA Filter
Media pack arrangement Multiple packs in V configuration Single flat or compact pack
Media area High within compact footprint High within compact depth
Typical airflow Often suited to higher airflow Depends on face area and design
Filter structure Rigid multi-pack frame Flat or compact frame
Typical applications Large AHUs, industrial HVAC, data centers Cleanrooms, terminal units, HVAC
Installation depth Usually deeper than flat mini-pleat Often more compact
Pressure drop Depends on media area and airflow Depends on media area and airflow

Neither construction is automatically better.

The right choice depends on system airflow, available depth, filter bank design, efficiency requirement, pressure drop target, and replacement strategy.

Related collection: Mini-Pleat HEPA Filters

H13 and H14 V-Bank HEPA Filters

Clean-Link can support H13 and H14 V-bank HEPA filter projects depending on the application and confirmed specification.

Efficiency should be selected together with:

  • Rated airflow
  • Initial pressure drop
  • Final pressure drop
  • Fan capability
  • Filter bank dimensions
  • Prefiltration
  • Operating hours
  • Dust concentration
  • Sealing
  • Testing requirements

For high-efficiency filter classification and testing, ISO 29463 provides relevant technical context.

Related guide: Understanding HEPA Filter Efficiency

Frame and Construction Options

V-bank HEPA filters require rigid frames to support multiple media packs.

Depending on project needs, Clean-Link can support different configurations.

Possible options may include:

  • Plastic composite frame
  • Galvanized steel frame
  • Aluminum frame
  • Custom rigid frame
  • Header frame
  • Box-style configuration

Frame selection should consider:

  • Filter weight
  • Installation method
  • Housing design
  • Mechanical strength
  • Corrosion exposure
  • Temperature
  • Gasket requirements
  • Replacement handling

Gasket and Sealing Options

Proper sealing is important for HEPA filter performance.

Clean-Link can support gasket options such as:

  • Upstream gasket
  • Downstream gasket
  • Full-face gasket
  • Custom gasket location
  • Foam gasket
  • EPDM gasket where applicable

The gasket should match the housing compression surface and installation direction.

A high-efficiency filter can still lose system performance if air bypass occurs around the frame.

Related article: Air Filter Bypass Leakage

Airflow and Pressure Drop

V-bank filters are often selected specifically because the system needs to handle higher airflow in a limited filter area.

Important parameters include:

Factor Why It Matters
Rated airflow Defines air volume per filter
Face velocity Influences resistance and loading
Initial pressure drop Shows resistance when new
Final pressure drop Supports replacement planning
Media area Helps determine airflow handling
Number of V packs Affects total filter area and structure
Filter depth Affects installation compatibility
Fan capability Determines whether the system can handle resistance
Prefiltration Helps protect the HEPA stage
Dust load Affects filter life and pressure rise

For high-airflow projects, Clean-Link can review the filter specification together with system air volume and available installation space.

V-Bank HEPA Filters for Data Centers

Data centers often require high airflow to support cooling systems and protect sensitive equipment from airborne contamination.

V-bank filters may be suitable where:

  • Air volumes are high
  • Filter space is limited
  • Low system resistance is important
  • Fine particle control is required
  • Long replacement intervals are preferred

The actual filter class and system configuration should be selected according to the HVAC design, outdoor air quality, recirculation strategy, and equipment protection goals.

Related page: Data Center Air Filtration

Industrial V-Bank HEPA Filter Applications

V-bank HEPA filters can also be used in industrial systems that require high-efficiency filtration with higher airflow capacity.

Typical applications include:

  • Manufacturing plants
  • Pharmaceutical facilities
  • Biotechnology facilities
  • Laboratories
  • Electronics manufacturing
  • Industrial HVAC
  • Process ventilation
  • Commercial buildings
  • Data centers
  • OEM equipment
  • High-airflow air handling units

For industrial systems, particle load and upstream filtration should also be considered.

Related page: Industrial Air Filtration Solutions

Prefiltration Before V-Bank HEPA Filters

HEPA filters should generally not be used as the only filtration stage in dusty environments.

Upstream filtration can help reduce coarse and medium particle load before air reaches the V-bank HEPA filter.

A staged arrangement may include:

  1. Prefilter
  2. Medium-efficiency panel or pocket filter
  3. V-bank HEPA filter

This can help:

  • Reduce HEPA loading
  • Slow pressure drop increase
  • Support longer service life
  • Protect the high-efficiency stage
  • Improve maintenance planning

Related guide: Multi-Stage Air Filtration Systems

Standard and Custom V-Bank HEPA Filter Sizes

Clean-Link can support standard and custom V-bank HEPA filter dimensions.

Custom requirements may include:

  • Length
  • Width
  • Depth
  • Number of V packs
  • H13 / H14 requirement
  • Frame material
  • Header structure
  • Gasket location
  • Rated airflow
  • Pressure drop target
  • OEM packaging
  • Labeling
  • Drawing-based production

For replacement projects, actual dimensions should be confirmed whenever possible.

Related page: Custom HEPA Filters

Replacement V-Bank HEPA Filters

Replacing an existing V-bank HEPA filter requires more than matching the external dimensions.

Buyers should confirm:

Requirement What to Check
Dimensions Actual length × width × depth
Efficiency H13, H14 or current requirement
Airflow Rated airflow per filter
Pressure drop Existing data if available
Frame Material and structure
Number of V packs Helps match filter construction
Gasket Position and material
Header Box or header configuration
Application HVAC, data center, industrial, laboratory
Quantity Current and repeat demand

If complete information is unavailable, start with:

Photo + dimensions + application

How to Select a V-Bank HEPA Filter

Before requesting a quotation, confirm:

  • Application
  • Filter dimensions
  • Efficiency class
  • Rated airflow
  • Pressure drop requirement
  • Fan capability
  • Frame material
  • Number of V packs
  • Gasket configuration
  • Installation depth
  • Current filter model or photo
  • Prefiltration stage
  • Dust concentration
  • Operating hours
  • Quantity
  • Testing requirements

The most important point is:

A V-bank HEPA filter should be selected according to airflow, media area, system resistance, and installation space—not only efficiency class.

Testing and Documentation

V-bank HEPA filter projects may require testing and documentation according to buyer specifications.

Clean-Link can support discussion of:

  • Dimensional inspection
  • Visual inspection
  • Frame and gasket inspection
  • Airflow resistance data where applicable
  • Efficiency-related data where applicable
  • Leakage or scan testing where applicable
  • Datasheets
  • Drawings
  • Individual reports where required
  • OEM documentation support

Testing method and acceptance requirements should be confirmed before production.

Request a V-Bank HEPA Filter Quote

Need a V-bank HEPA filter for a high-airflow HVAC system, data center, industrial facility, laboratory, or OEM project?

Send Clean-Link:

  • Filter dimensions
  • H13 / H14 requirement
  • Rated airflow
  • Pressure drop requirement, if available
  • Frame type
  • Gasket configuration
  • Number of V packs, if known
  • Application
  • Existing filter photo or drawing
  • Quantity
  • Testing requirements

If you do not have the full specification, start with:

Photo + dimensions + airflow + application

Clean-Link can help review what should be confirmed next.

Request a Quote →

FAQ

What is a V-bank HEPA filter?

A V-bank HEPA filter uses multiple mini-pleat media packs arranged in a V-shaped configuration inside a rigid frame. This provides high media area within a compact filter footprint.

Why are V-bank HEPA filters used for high airflow?

The V-shaped arrangement increases available media area, which can help manage higher airflow while controlling resistance. Actual airflow capacity depends on filter size, efficiency, media area, and system conditions.

Are V-bank HEPA filters available in H13 and H14?

Yes. Clean-Link can support H13 and H14 project requirements depending on filter design, airflow, pressure drop, and application.

Is a V-bank HEPA filter always low pressure drop?

No. Pressure drop depends on media area, pleat geometry, efficiency, airflow, filter depth, and loading. V-bank construction provides design flexibility for pressure drop optimization but does not guarantee low resistance.

What is the difference between a V-bank HEPA filter and a mini-pleat HEPA filter?

A V-bank filter uses multiple mini-pleat packs arranged in a V configuration, while a standard mini-pleat HEPA filter typically uses a single compact media pack.

Where are V-bank HEPA filters commonly used?

Common applications include high-airflow HVAC systems, data centers, industrial ventilation, laboratories, commercial buildings, pharmaceutical facilities, and OEM air handling equipment.

Can V-bank HEPA filters be customized?

Yes. Custom options may include dimensions, efficiency class, airflow, pressure drop, frame material, number of V packs, gasket, header configuration, and packaging.

What information is needed for a quote?

Provide dimensions, efficiency class, rated airflow, pressure drop requirement if available, frame type, gasket configuration, application, quantity, and an existing filter photo or drawing where possible.